SERIES
R302


INSTALLATION INSTRUCTIONS

 

THE FOLLOWING INSTRUCTIONS ASSUME THAT THE LUMINAIRE TO BE RETROFITTED HAS BEEN STRIPPED OF EXISTING COMPONENTS (DOOR ASSEMBLY, LAMPS, BALLAST COVER, SOCKET PLATES AND LAMPHOLDERS) AND THAT POWER TO LUMINAINR HAS BEEN TURNED OFF...

IF YOU ARE USING A SIDE MOUNTING BRACKET.

ATTACH SAFETY CABLE MOUNTING ANGLES (PART NO. 6743) TO TOP OF HOUSING.APPROXIMATELY 10"
FROM EACH END OF FIXTURE AS SHOWN IN THE ILLUSTRATION WITH "TEC" SELF.DRILLING SCREW.

INSTALL MOUNTING BRACKETS AT EACH END OF FIXTURE. USE PART NO. 6754 AND FASTEN TO
END CAP OF FIXTURE HOUSING IF INSTALLING TWO LAMP RETRO-LINERS IN RECESSED FIXTURES.
USE PART NO. 6756 AND FASTEN TO TOP OF HOUSING IF INSTALLING THREE LAMP RETRO-LINERS IN
RECESSED FIXTURES OR IF INSTALLING EITHER TWO OR THREE LAMP ASSEMBLIES IN SURFACE
MOUNTED LUMINAIRES. USE POSITIONING GAGE SUPPLIED TO INSTALL 6754 MOUNTING ANGLE
APPROXIMATELY 5/8" BELOW TOP OF HOUSING. WHEN INSTALLING PART NO 6756, CENTER THE
BRACKET ON THE LONGITUDINAL CENTERLINE OF THE HOUSING, WITH THE "HOOK" SIDE OF THE
PART.IN CONTACT WITH THE END CAP, THEN FASTEN TO TOP OF HOUSING WITH TEC SCREWS.

IF YOU ARE USING A TOP MOUNTING BRACKET

HANG RETROFIT ASSEMBLY FROM MOUNTING ANGLES WITH SAFETY CABLE "S" HOOK.AND SCREW
GROUND WIRE TO TOP OF HOUSING WITH TEC SCREW TO PROVIDE SECURE "GROUND" FOR THE
ELECTRICAL COMPONENTS OF THE ASSEMBLY.

CONNECT POWER SUPPLY LEADS TO BALLAST LEADS.

INSERT END OF RETROFIT ASSEMBLY WITH FIXED SOCKET PLATE INTO HOUSING SLIDING
SOCKET PLATE OVER FLANGE OF PART NO. 6754 ON END CAP OR ENGAGE HOOKS ON PART NO. 6756
INTO SLOTS IN END OF SOCKET PLATE SUCH THAT THE END OF THE ASSEMBLY IS SUPPORTED BY
THE MOUNTING BRACKET. RAISE OPPOSITE END OF ASSEMBLY INTO THE FIXTURE HOUSING AND
SLIDE THE TELESCOPING SOCKET PLATE INTO POSITION ON THE MOUNTING BRACKET.

TIGHTEN THE SCREWS SECURING THE TELESCOPING SOCKET PLATE.

INSTALL LAMPS, TURN ON POWER, CLEAN AND REPLACE DOOR ASSEMBLY.

WHEN INSTALLING RETROFIT ASSEMBLIES IN SURFACE LUMINAIRES .ALWAYS CHECK INSIDE LENGTH OF FIXTURE HOUSING. IF LONGER THAN 47-7/8",.LAMPHOLDERS MAY HAVE TO BE SUPPORTED WITH
ADDITIONAL BRACKETS, AND .PART NO 6756 MOUNTING BRACKET WILL HAVE TO BE SPACED IN FROM
THE END.CAP. WHEN THERE IS ANY DOUBT CONCERNING PROCEDURE, PLEASE CONTACT
YOUR LOCAL WELLMADE SALES AGENT.

 

 

<- Front of Page              WELLMADE PRODUCTS 1715 KIBBY ROAD - MERCED - CALIFORNIA - 95340 (209) 723-9120 - FAX: (209) 723-9131